Add to Cart
Product introduction
Rsp-2400 is a 2.4KW single group output enclosure type changing AC to DC power supply. The whole series of input voltage range from 180 to 264VAC and can provide DC output to meet most industrial needs. Each model can be air-cooled by internal speed control fan, and the working temperature can reach 70℃. In addition,the RSP-2400 provides a wide range of design flexibility with built-in functions such as adjustable output voltage, current equalization, remote on/off control and auxiliary power supply.
Product features
Built-in active power factor correction (ACTIVE PFC).
Efficiency up to 91.5%.
Built-in DC fan for forced cooling.
Output voltage adjustable.
Active parallel connection up to 7200W (2+1).
Protection type: short circuit / overload / over voltage / over temperature.
Spray moisture repellent optional.
Product specification
Output |
DC voltage | 48V |
Rated current | 50A | |
Current range | 0 ~ 50A | |
Rated power | 2400W | |
Ripple and Noise (Max) | 200mVp-p | |
Voltage adjustment range | 43 ~ 56V | |
Voltage Accuracy | ±1.0% | |
Linear adjustment rate | ±0.5% | |
Load regulation rate | ±0.5% | |
Start-up, rising time | 1000ms, 80ms (at full load). | |
Hold time | 12ms (at full load). | |
Input |
Voltage range | 180 ~ 264VAC 254 ~ 370VDC |
Frequency range | 47 ~ 63Hz | |
Power factor (Type) | 0.95/230VAC (at full load). | |
Efficiency (Type) | 91.5% | |
AC current (Type) | 15.5A/180VAC 12A/230VAC | |
Inrush current(Type) | 60A/230VAC | |
Leakage current | <2.0mA / 240VAC | |
Protection |
Overload |
00 ~ 112% of the rated output power; The user can continuously adjust the constant current limit or the constant current limit delay for 5 seconds after shutting down the output voltage and resuming after restarting |
Overvoltage |
57.6~67.2V; Protection type: Shuts down the output voltage, recovers after restart |
|
Overtemperature | The output voltage is turned off and automatically recovers when the temperature drops | |
Working environment |
Operating temperature | -20 ~ +70°C (refer to "subtraction curve") |
Operating humidity | 20 ~ 90% RH non-condensing | |
Storage temperature, humidity | -40 ~ +85℃, 10 ~ 95% RH |